33 min read

BASIX Water Efficiency NSW: Targets and Requirements

By Team CE on May 25, 2026 2:16:33 PM

The BASIX Water section assesses how a proposed residential development will reduce its demand for potable water compared with the NSW residential benchmark.

The result is influenced by water-efficient fixtures, landscape areas, low-water-use planting, rainwater or other alternative water sources, pools and spas, and any central systems or common areas associated with the development.

A passing water result is not produced by one universal requirement. The appropriate combination depends on the project location, dwelling type, landscape demand, water systems and commitments selected within the assessment.

Topics: BASIX Residential Compliance
20 min read

BASIX and Building Orientation in NSW | Certified Energy

By Team CE on May 25, 2026 1:52:37 PM

NSW Residential Thermal Performance Guide

Building orientation affects when sunlight reaches each elevation, how much solar heat enters through glazing and how readily a home can balance winter warmth with summer protection.

 

Orientation is one of the fundamental inputs shaping residential thermal performance. It influences the solar exposure of walls and windows, the usefulness of winter sunlight, the risk of summer overheating and the effectiveness of different shading arrangements.

Within a BASIX thermal comfort assessment, orientation does not operate as a standalone compliance item. Its effect is expressed through the interaction between the building layout, glazing, shading, insulation, thermal mass, ventilation and the project’s climate conditions.

This guide focuses specifically on that relationship. For the wider BASIX process, targets and NSW submission pathway, visit the BASIX Knowledge Hub.

Topics: BASIX Residential Compliance
22 min read

What Is BASIX? NSW Certificate and Assessment Explained

By Team CE on May 23, 2026 2:41:25 PM

What Is BASIX?

BASIX is the Building Sustainability Index used for residential development in New South Wales. It forms part of the NSW planning and approval system and establishes project-specific requirements for water use, energy use and thermal performance.

A BASIX assessment uses information about the proposed dwelling, including its location, size, glazing, construction, insulation, water measures and building services. The assessment also records construction materials so the embodied emissions associated with the development can be calculated and reported.

Once the applicable BASIX requirements have been satisfied, a BASIX Certificate can be generated. The Certificate lists the sustainability commitments that must correspond with the approval plans and be carried through into the completed development.

Topics: BASIX Residential Compliance
20 min read

When is BASIX Required in NSW? | BASIX Certificate Requirements

By Team CE on May 23, 2026 2:04:24 PM

NSW Residential Compliance Guide

BASIX is required for most new residential development in New South Wales, as well as qualifying alterations, additions, swimming pools and spas.

 

Determining whether BASIX applies is one of the first residential compliance questions to resolve before lodging a Development Application or Complying Development Certificate application in NSW.

The requirement is not based only on whether a project appears large or whether it changes the thermal performance of the home. BASIX applicability is established through defined development types, cost thresholds and pool or spa capacity thresholds.

This guide focuses specifically on when a BASIX Certificate is required. For a broader explanation of BASIX targets, commitments and the assessment process, visit the BASIX Knowledge Hub.

Topics: BASIX Residential Compliance
30 min read

BASIX Materials Index and Embodied Emissions NSW

By Team CE on May 23, 2026 1:44:43 PM

The BASIX Materials Index calculates and reports the embodied emissions associated with construction materials entered for an applicable residential development in New South Wales.

Unlike the BASIX Water and Energy sections, the Materials Index does not currently apply a separate score or emissions limit that the project must achieve. Its present role is to quantify material-related emissions and record them within the BASIX assessment.

The result depends on the proposed building geometry, construction areas and selected material systems. Accurate information is therefore important even though the Materials Index is currently a reporting requirement rather than a standalone performance target.

Topics: BASIX Residential Compliance
30 min read

Passive Design Principles for BASIX and NatHERS | Certified Energy

By Team CE on May 23, 2026 1:35:38 PM

Passive design uses the building’s orientation, form, windows, shading, insulation, ventilation and construction to respond to the local climate before mechanical heating and cooling systems are considered.

Within BASIX and NatHERS, these decisions influence the modelled heating and cooling demand of a residential design. A well-coordinated passive response can improve thermal performance, reduce pressure on later specifications and make the final commitments easier to deliver.

Passive design is not a checklist of universally beneficial features. Each measure affects the others, and the appropriate balance depends on the climate, site, dwelling form and way the home is expected to operate.

Topics: BASIX Residential Compliance
34 min read

How Window Size, Frames and Glass Affect BASIX | Certified Energy

By Team CE on May 23, 2026 1:30:27 PM

Windows are one of the most influential parts of a residential thermal-performance assessment. They provide daylight, views and ventilation, but they can also transfer heat more readily than insulated walls, roofs and floors.

Within BASIX and NatHERS, window performance is determined by more than whether the glass is single or double glazed. The complete window system—including the frame, glass, opening type, size, orientation and shading—affects the modelled heating and cooling demand of the dwelling.

The final assessment may establish maximum U-values, acceptable Solar Heat Gain Coefficient ranges and dwelling-specific window requirements. Those values must then be coordinated with the architectural plans, window schedule, supplier information and installed products.

Topics: BASIX Residential Compliance
24 min read

Understanding SHGC and U-Values | BASIX and Window Performance

By Team CE on May 23, 2026 1:26:02 PM

Glazing Performance Reference

U-value and Solar Heat Gain Coefficient describe two different aspects of window performance: how readily heat passes through the complete window and how much solar heat it admits.

 

U-value and SHGC are commonly shown in BASIX and NatHERS documentation because windows can transfer heat through both conduction and solar radiation. The two values describe different physical behaviours and should not be interpreted as interchangeable measures of general window quality.

A lower whole-window U-value generally indicates better resistance to heat flow. The preferred SHGC is more contextual: a lower value reduces solar heat gain, while a higher value allows more solar warmth to enter. Either may be useful depending on climate, orientation, shading and the heating or cooling issue being addressed.

This guide focuses on understanding and reading these two technical values. For the wider design relationship between window size, orientation, frames and shading, see Window Performance and BASIX.

Topics: BASIX Residential Compliance
35 min read

BASIX Thermal Performance NSW: Heating and Cooling

By Team CE on May 23, 2026 1:22:39 PM

Thermal performance is the part of BASIX that assesses how much artificial heating and cooling a proposed dwelling is expected to require. It considers how the building envelope responds to the local climate before the efficiency of the installed heating or cooling equipment is taken into account.

The result is influenced by the dwelling geometry, orientation, glazing, shading, insulation, construction systems and exposure to external conditions. BASIX compares the estimated or simulated heating and cooling loads with the maximum loads allowed for the project.

A project must satisfy the applicable heating and cooling requirements using an accepted assessment method. Depending on the dwelling and project pathway, this may be the BASIX DIY Method, NatHERS Simulation Method or Passive House Standard method.

Topics: BASIX Residential Compliance
4 min read

BASIX for Alterations and Additions NSW | BASIX Renovation Requirements

By Team CE on May 23, 2026 1:09:21 PM

BASIX for Alterations and Additions in NSW

Topics: BASIX Accreditations Energy Efficiency Residential